Name: | Flush diaphragm pressure transmitter |
---|---|
Model: | SMP858-TSD-H |
Measuring range: | 10kPa~10MPa |
Accuracy: | ±0.2% URL, ±0.5% URL |
Working temperature: | -40~120℃ |
Signal output: | 4~20mA, 4~20mA+HART, 0.5~4.5VDC, Modbus-RTU/RS485 |
Power supply: | 10.5~55VDC |
Measuring range: 10kPa~10MPa
Output signal: 4~20mA, 4~20mA+HART, 0.5~4.5VDC, Modbus-RTU/RS485
Reference accuracy: ±0.2% URL, ±0.5% URL
Media temperature: -40~120℃
Protection class: IP67
Stability: ±0.2% URL/ years
Process connection: M20*1.5 male, G1/2 male, G1 male, G1-1/2 male...
Approvals: EHEDG, 3A, CE, EX-proof certificate
Double diaphragm overload protection structure can easily cope with high overload test.
Isolated air cavity design to prevent condensation and avoid pollution to the media.
Flush diaphragm up to +150°C per EHEDG.
Wetted parts with 316 stainless steel and O-ring from EPDM.
Filling fluid with hygiene standard in line with FDA certification.
Designed for food and pharmaceutical industry, suitable for CIP/SIP cleaning and sterilization.
SMP858-TSD adopts full isolation seal structure to eliminate the humidity effects, suitable for severe wet cleaning occasion. Double diaphragm overload protection structure to achieve the highest overload pressure 42MPa, suitable for severe pressure overload situations. Seven segment temperature range 20 linear point reaches 160 pressure calibration points, suitable for severe temperature variation. All these leading manufacturing techniques redefined the highest quality of hygienic pressure transmitter.
Pharmacy & food
Milk & beverage